REMOTE FUEL FILL PANEL
A U/L Listed, NEMA 3R enclosure, remotely mounted that is used to monitor tank fuel level filling activities. At 90% fuel fill, alarm horn activates and a light illuminates (alarm horn and silence switch included). At 95% an alarm horn sounds, light illuminates, and an optional N/O solenoid valve (opt #361), if installed, closes allowing no more fuel to enter tank. This model, #226, is designed for mounting onto a wall, post, etc.
|
|
|
| |
|
|
|
|
|
WALL-FLUSH MOUNTING of REMOTE FUEL FILL PANEL
Necessary brackets needed to recess mount the panel enclosure (not the door) into wall. Does not include option #226
|
|
|
|
|
|
ASSISTING PUMP and MOTOR for REMOTE FUEL FILL PANEL
The controls, brackets, etc. necessary to mount a single pump and motor to pump fuel to a non-gravity fill main storage tank. NOTE: Specify / order pump and motor separately according to requirements.
|
|
|
REMOTE FUEL FILL STATION
|
|
|
|
 |
|
|
|
A lockable, U/L Listed, NEMA 3R, dual-door enclosure designed to accommodate delivery truck curb-side filling of storage tank via hose connection. Inside are two compartments:
- the right side has a brass Cam-and-Groove fitting, a check valve, a
manual shut-off valve, and a 7-1/2 containment sump;
- the left (isolated) side has the electrical components required to monitor
fuel activities and report abnormal conditions.
When the tank being filled reaches a 90% set point, a warning light comes on and an alarm horn sounds. If filling continues, a second light comes on at 95% capacity and an alarm horn again sounds. At this time, an optional solenoid valve (opt 361) will close allowing no more fuel to enter the tank. A silence switch and remote contact outputs are standard.
Remote Fill Stations are available in three configutations:
|
|
|
230-22 230-32 230-33
|
2" cam-and-Groove fill connection with 2" plumbing and outlet. 3" cam-and-Groove fill connection with 2" plumbing and outlet. 3" cam-and-Groove fill connection with 3" plumbing and outlet.
(Electrical components available in 120vac, 12vdc, and 24vdc)
|
|
|
|
|
|
WALL-FLUSH MOUNTING of REMOTE FILL STATION
Necessary brackets needed to recess mount the fill station enclosure (not the door) into wall. Does not include option #230
|
|
|
|
|
|
ASSISTING PUMP and MOTOR for REMOTE FILL STATION
The controls, brackets, etc. necessary to mount a single pump and motor to pump fuel to a non-gravity fill main storage tank. NOTE: Specify / order pump and motor separately according to requirements.
|
|
|
FUEL DELIVERY CONTROL STATION
|
A lockable, weatherproof, free-standing enclosure with a 20-gallon spilled fuel containment area. The 2”or 3” main fuel line features:
- a brass Cam-and-Groove fitting for standardized lock-on filling;
- a check valve to prevent “back-fill” flooding
Any spilled fuel falls into the 20-gallon sump where it can be either manually drained or pumped back into the main fuel line using an included hand pump.
|
|
232-22 232-32 232-33
|
2" cam-and-Groove fill connection with 2" plumbing and outlet. 3" cam-and-Groove fill connection with 2" plumbing and outlet. 3" cam-and-Groove fill connection with 3" plumbing and outlet.
|
|
|
|
|
|
ASSISTING PUMP and MOTOR for FUEL DELIVERY CONTROL STATION
The controls, brackets, etc. necessary to mount a single pump and motor to pump fuel to a non-gravity fill main storage tank. NOTE: Specify / order pump and motor separately according to requirements.
|