Pryco Day Tanks come in three general design types: Standard, Manual and Trim:
  • Standard and Manual tanks have the same physical dimensions.  
  • Manual tanks however do not have a mounted pump, motor, float switch, and do not
    have a cover unless it is U/L Listed.  
  • Standard and the Trim tanks have the same standard equipment (shown below);
    however, the Trim design has a smaller footprint and  is taller.  

    All Pryco Day Tanks are fabricated of heavy gauge steel by certified welders.  Each tank
    complies with NFPA 30 and is tested to 5 psi.

    Standard features include:
    Removable 6½" Square Inspection Plate
    w/Gasket
    Tank Drain (Sized To Tank Capacity)
    Fuel Level Gauge
    1/3 hp thermally protected, 120vac, 1ph,
    60hz, motor [Note 1]
    Heavy Duty Float Switch [Note 1]
    2 gpm bronze gear pump w/stainless
    steel shafts [Note 1]
    “Press-to-Test” Switch [Note 1]
    Lift Lugs (on tanks 50 gallons and  over)
    "Pump Running" Indicator Light [Note 1]
    Removable top cover [Note 2]
    Four - 1" NPT Threaded Pipe Connections
    Epoxy coating inside
    One - 2" NPT Threaded Pipe Connection
    for Tank Vent
    Pryco (medium) Gray exterior paint (or an
    industrial color of choice)
[1]  Not included on Manual Day Tanks
[2]  Not included on non-U/L Listed Manual Day Tanks
PRYCO DAY TANKS
The Best Thing Fueling
The content of this website is copyrighted (c) 2006 - All rights are reserved.
Please refer to our site
disclaimer.
STANDARD Day Tank  
has all the features and options for maximum control
and function
MANUAL Day Tank      
same size as a Standard except has no pumping or
control capabilitiessame size as a Standard except has
no pumping or control capabilities
TRIM Day Tank              
similar to the Standard in control and functionality but
with a smaller footprint for those tight places
RUPTURE BASIN      
150% and 200% custom built to fit the dimensions of
the above tanks.  Weatherproof covers (shown) are
available - see
Option #s 385 & 386.
U/L LISTED TANKS

Most Day Tank or Subbase Tank can be U/L Listed (Label 142).  In addition to the above features, all U/L Listed tanks
additionally have:
  • internal extra strength reinforcement;
  • a properly sized emergency vent (see  “U/L VENT” columns in appropriate tables on the following pages); and,
  • a U/L Listed label.

Pryco’s unique U/L File Numbers are:

    MH12807 which pertain to Day Tanks - specifically:
  • Aboveground Flammable for Liquid Tanks (Day Tanks);
  • Secondary Containment Aboveground Flammable for Liquid Tanks  (Day Tanks with Double Wall
    Construction); and,
  • Open Top Diked Aboveground Flammable for Liquid Tanks (Day Tanks with a Rupture Basin).

    MH17469 which pertain to Sub-base Tanks - specifically
  • Generator Base Tanks (Sub-base Tanks);
  • Secondary Containment Generator Base Tank (Sub-base Tanks with Double Wall Construction); and,
  • Open Top Diked Generator Base Tank (Sub-base Tanks with a Rupture Basin).

    E102372 which pertains to Industrial Control Panels - specifically our Enclosed Industrial Control Panel
    (option #465).