Dimensions and Drawings
TANK
SIZE
TANK + LEGS DIMENSIONS
DESIGN
LISTING
MODEL
NUMBER
TANK
WEIGH
[3]
U/L VENT
SIZE
TANK
DRAWING
RUPTURE BASIN [4]
150%
TANK
CAP.
200% TANK CAP.
WIDTH
DEPTH
[1]
HEIGHT
[2]
WEIGHT
[5]
DWG
5
30
14
22.5
Basic
. PY5DW
165
n.a.
Call
Factory



NOTE
150%
Rupture
Basins
not
available
for
Double
Wall
Day
Tanks
Call
Factory
Call
Factory
U/L
. PY5ULDW
170
2"
10
30
18
17
Basic
. PY10DW
213
n.a.
10-25
Gal.
Tank
Drawings

Click
Here
87
10-25
Gal.
200%
Rupture
Basin
Click
Here
U/L
. PY10ULDW
217
2"
15
30
18
23
Basic
. PY15DW
250
n.a.
87
U/L
. PY15ULDW
255
2"
25
30
18
28
Basic
. PY25DW
281
n.a.
108
U/L
. PY25ULDW
286
2"
50
30
24
35
Basic
. PY50DW
367
n.a.
50-150
Gal.
Tank
Drawings

Click
Here
169
50-150
Gal.
200%
Rupture
Basin

Click
Here
U/L
. PY50ULDW
371
2"
60
30
24
43
Basic
. PY60DW
420
n.a.
183
U/L
. PY60ULDW
428
3"
75
30
24
48
Basic
. PY75DW
454
n.a.
207
U/L
. PY75ULDW
461
3"
100
30
30
48
Basic
. PY100DW
502
n.a.
249
U/L
. PY100ULDW
509
3"
150
30
42
48
Basic
. PY150DW
604
n.a.
325
U/L
. PY150ULDW
611
3"
200
30
60
51.5
Basic
. PY200DW
882
n.a.
200-1000
Gal.
Tank
Drawings

Click
Here
457
200
Thru
1000
Gal.
200%
Rupture
Basin

Click
Here
U/L
. PY200ULDW
895
4"
275
33
72
51.5
Basic
. PY275DW
1111
n.a.
531
U/L
. PY275ULDW
1124
4"
300
34
72
51.5
Basic
. PY300DW
1124
n.a.
537
U/L
. PY300ULDW
1137
4"
400
40
78
51.5
Basic
. PY400DW
1285
n.a.
603
U/L
. PY400ULDW
1297
4"
500
48
78
51.5
Basic
. PY500DW
1396
n.a.
652
U/L
. PY500ULDW
1409
4"
600
48
86
51.5
Basic
. PY600DW
1489
n.a.
694
U/L
. PY600ULDW
1501
4"
700
54
88
51.5
Basic
. PY700DW
1622
n.a.
743
U/L
. PY700ULDW
1635
6"
800
58
92
51.5
Basic
. PY800DW
1897
n.a.
791
U/L
. PY800ULDW
1910
6"
900
62
96
51.5
Basic
. PY900DW
2025
n.a.
840
U/L
. PY900ULDW
2056
6"
1000
64
102
51.5
Basic
. PY1000DW
2110
n.a.
888
U/L
. PY1000ULDW
2141
6"
SIZE
(U.S.
Gal.)
WIDTH
DEPTH
[1]
HEIGHT
[2]
DESIGN
LISTING
MODEL NUMBER
TANK
WEIGHT
[3]
U/L VENT
SIZE
TANK
DRAWING
150%
TANK
CAP.
WEIGHT
[5]
DWG
200% TANK CAP.
OVERALL TANK
RUPTURE BASIN [4]
The content of this website is copyrighted (c) 2006 - All rights are reserved.
Please refer to our site
disclaimer.
Other Day Tank Designs
STANDARD DAY TANKS - DOUBLE WALL
Other Standard Tanks
Specifications and
Chart Drawing
Single Wall Tanks
or
Select By Size
TABLE NOTES:

1 - Depth dimension is inner tank front to back (legs will extend beyond both front and back - see tank drawings).

2 - Height dimension is:
a - the inner tank plus 1-1/2" inner legs (the inner legs define a 1-1/2" secondary containment area), plus
b - the outer legs. (The outer leg height is 3" for 10 through 150 gallons standard day tanks, and 1-1/2" for
200 through 1000 gallons standard day tanks.

Add removable cover height to above shown height to determine overall height.  Removable cover height is
12-1/2" for a single pump/motor tank-mounted configuration.  (Contact factory for other pump/motor
configurations.)  Add this to height dimension show above to determine overall height.

3 - Approximate weight of day tank (options not considered) - Includes pump, motor, and related controls.

4 - Rupture Basin capacity is relative to the inner day tank capacity.  

5 - Add rupture basin weight to day tank weight for overall unit weight.
PY25ULDW with several options
including:
  • 700 - FCM
  • 295 - Leak Detector - D/W

The enclosure on the side houses
motor starters.
Tank size (capacity) is measured in U.S. Gallons.  All dimensions are in inches and weights are shown in US pounds.